This table shows a complete list of the Frymaster 3000 Controller Error Codes in one place.
Your Frymaster 3000 Controller may not show all the error codes listed here. Additionally, the wording for your Frymaster 3000 Controller may be slightly different based on what version of Frymaster 3000 Controller you have.

ERROR CODE TABLE

 CODEERROR MESSAGEEXPLAINATION
E01REMOVE DISCARD (Right)A product cook is started on the right side of a split vat or in a full vat that has a different setpoint other than the current vat temperature.
E02REMOVE DISCARD (Left)A product cook is started on the right side of a split vat or in a full vat that has a different setpoint other than the current vat temperature.
E03ERROR TEMP PROBE FAILURETEMP Probe reading out of Range.
E04HI 2 BADHigh Limit Reading is out of Range.
E05HOT HI 1High limit temperature is past more than
410°F (210°C), or in CE countries, 394°F
(202°C).
E06HEATING FAILUREA component has failed in the high limit circuit such as controller, interface board, contactor or open-high limit.
E07ERROR MIB SOFTWAREInternal MIB software error
E08ERROR ATO BOARDATO board connection lost; ATO board failure
E09ERROR PUMP NOT FILLINGDirty pad and it needs to be changed or it was bypassed; filter pump problem
E10ERROR DRAIN VALVE NOT OPENDrain valve was trying to open and confirmation is missing
E11ERROR DRAIN VALVE NOT CLOSEDDrain valve was trying to close and confirmation 7-6 is missing
E12ERROR RETURN VALVE NOT OPENReturn valve was trying to open and confirmation is missing
E13ERROR RETURN VALVE NOT CLOSEDReturn valve was trying to close and confirmation is missing
E14ERROR AIF BOARDMIB detects AIF missing; AIF board failure
E15ERROR MIB BOARDCooking controller detects MIB connections lost. Check software version on each controller. If versions are missing, check CAN connections between each controller. MIB board failure
E16ERROR AIF PROBEAIF RTD reading out of range
E17ERROR ATO PROBEATO RTD reading out of range.
E18Not used 
E19M3000 CAN TX FULLConnection between computers lost. Check for loose CAN cables between computers and MIB board. Check software version by pressing the TEMP button with the computers displaying OFF. If a computer displays only M3000 software, the computer may be defective.
E20INVALID CODE LOCATIONSD Card removed during update.
E21CHANGE FILTER PAPER
FILTER PAD PROCEDURE ERROR
(Change Filter Pad)
25 hour timer has expired or dirty filter logic has activated
Change filter paper and follow prompts.
E22OIL IN PAN ERROROil may be present in the filter pan.
Or, The MIB has reset the oil in pan flag.
E23CLOGGED DRAIN (Gas)Vat did not empty during filtration
E24AIF BOARD OIB FAILED (Gas)Oil back sensor failed
E25RECOVERY FAULTRecover time exceeded maximum time limit. Recovery time should not exceed
1:40 for electric or
2:25 for gas.
E26RECOVERY FAULT CALL SERVICERecovery time exceeded maximum time limit for two or more cycles.
Recovery time should not exceed 1:40 for electric.
E27LOW TEMP ALARMOil temperature has dropped 30°F (17°C) lower than setpoint in idle mode or 45°F (25°C) in cook mode.
(This message may appear if a product is dropped and the start cook button is not pressed immediately or if too large of cook loads are dropped.)
E28HIGH TEMP ALARMOil temperature has risen 40°F (4.4°C) higher than setpoint. If temperature continues to rise, high limit feature will shut the burner off when temperature reaches 425°F (218°C). ) Non-CE or 395°F (202°C) CE.

Need Additional Help?

Contact our service staff if you need additional assistance with understanding these codes or would like to make a service appointment to resolve an issue.